Monitor HotPlugging in ATI Proprietary Drivers in Week6 (archived)

InstructionsLink to the installation instructions
Monitor HotPluggingDetailed information on the testcase
Testcase (Report an issue with this testcase)
This is a legacy testcase, content is only available here: http://testcases.qa.ubuntu.com/Hardware/X/ProprietaryDrivers#Monitor HotPlugging
ReporterLast updateBugsComment
FailedMLindeblom2010-03-25 00:12
Second display is black with fglrx on Lucid (#546530)
In: fglrx-installer (Ubuntu)
Status: New
Importance: Undecided
Assignee: None
1 reports, 1 comments, 1 subscribers, 0 duplicates
546530

Results were unstable.
virtual was increased but screen was black.

ReporterLast updateBugsComment
Passeddarkmatter2010-03-24 21:34

setting monitor to extended desktop mode with
xrandr --output CRT1 --auto --left-of LVDS --auto
failed. I had to add
Virtual 3120 1050
into Section "Screen" Subsection "Display"

Add a test result